Need a Gas Fireplace Installed? Get Professional, SANS-Compliant Service for a Warmer, Safer Home!
We offer expert gas fireplace installation services β safe, efficient, and fully compliant with SANS (South African National Standards) regulations. Backed by a 2-year workmanship guarantee, our trained installers ensure your fireplace is set up safely and correctly the first time, so you can enjoy the warmth without the worry.
Why Choose Us for Your Gas Fireplace Installation?
- Your safety is our top priority β we follow all national compliance standards.
- Certified professionals with years of experience in residential gas installations.
- Perfect integration into your space β we ensure your fireplace is fitted correctly and functions flawlessly.
- All workmanship backed by a 2-year warranty for total peace of mind.
- Need help with cutouts or wall modifications? Weβll coordinate with specialists when needed.
Fireplace Options to Consider
Natural Vent Fireplaces β These use a flue that vents through an external wall or chimney. Classic and reliable.
Ventless Fireplaces β Great for efficient heating without external vents. Just ensure the room size meets safety requirements β weβll assess and guide you.

Whatβs Included in a Standard Installation?
- Standard External gas Installation kit. (The Standard Kit material breakdown can be found below).
- Labour for drilling and routing gas line access between the appliance and gas cylinder location.
- Weβll install the regulator and gas line, fit an emergency shut-off valve, fit the flexi copper tubing and provide all other materials needed to complete the installation safely and professionally.
- Removal of old units (if applicable), connection of the new fireplace, and full system testing.
- Issue Certificate of Compliance (CoC).
- Friendly, efficient service and post-installation guidance.
Please note: Some gas fireplaces require specific ventilation or space clearances. If structural changes are needed, weβll advise and arrange qualified contractors as needed β additional charges may apply.
* A gas fireplace requires a minimum of 1 x 48kg gas cylinder to operate correctly.
*Cages are optional


Gas Line Installation β Fireplace Consideration
For any project where a fireplace may be placed in the center of a roomβor any location away from perimeter wallsβitβs crucial to plan ahead for the necessary gas line placement. If the gas line needs to be chased into or run through the concrete foundation, this work must be completed before any flooring, tiling, or finishing surfaces are installed.
Why it matters:
- Retrofitting gas lines after flooring is installed can be costly, time-consuming, and may damage finished surfaces.
- A central fireplace requires a concealed gas supply, which often means embedding the line beneath or within the slab. In some cases we can run it through a ceiling.
- By installing the gas line early, you avoid unnecessary demolition later and ensure a clean, efficient setup.
Best Practice:
Always install gas lines to any potential fireplace locations during the rough-in phaseβbefore any flooring or surface finishes are laid. Even if the fireplace is a βmaybe,β itβs far easier and more cost-effective to prepare for it now than to retrofit later.
Gas Fireplace Bottle Installation Setups

Single External Installation Kit
* 300mm Pigtail
* Astro low pressure wall mounted regulator + Bracket
* Straight Male 12/16 x 3/8
* 5m PEX - AL - PEX PIPE 12/16 Gas line. Additional @R75/m
* 2 Pex Elbows 12/16. Additional Elbows @R75/Elbow
* Emergency Shutoff Valve 12/16 Pex
* LPG Gas Emergency Shutoff Valve Plate
* Hosetail 12/16 Pex
* 2m Orange Hose + Clamps
* 1m Chain and anchor
* Conduit Sleeve + Brackets
* Core Drill Through Wall Partition
* Labour
* Issue Lp Gas CoC ( Certificate of Conformity )

Dual External Installation Kit
* 2 x 300mm Pigtail
* Changeover Valve
* Astro low pressure wall mounted regulator + Bracket
* Straight Male 12/16 x 3/8
* 5m PEX - AL - PEX PIPE 12/16 Gas line. Additional @R75/m
* 2 Pex Elbows 12/16. Additional Elbows @R75/Elbow
* Emergency Shutoff Valve 12/16 Pex
* LPG Gas Emergency Shutoff Valve Plate
* Hosetail 12/16 Pex
* 2m Orange Hose + Clamps
* 1m Chain and anchor
* Conduit Sleeve + Brackets
* Core Drill Through Wall Partition
* Labour
* Issue Lp Gas CoC ( Certificate of Conformity )

Optional Cages
Cages are only required under the following,
- Public access ( No gates to stop public from accessing your property.
- Complex/Estate's Common Property
- Under windows to reduce distances
- Under electric fencing to reduce distances
Often clients prefer cages to protect the cylinders from pets, kids or theft prevention.
Submit A Contact Request Form
Our Partners
Call Us Now β 067-495-7831
- Gas Installations Fourways
- Gas Installations Broadacres
- Gas Installations Bryanston
- Gas Installations Dainfern
- Gas Installations Dainfern Ridge
- Gas Installations Douglasdale
- Gas Installations Duxberry
- Gas Installations Edenburg
- Gas Installations Jukskei Park
- Gas Installations Kyalami